H₂ Membrane Analyzer
Hollow-fiber · PSA stageReal-time permeance, recovery, and purity monitoring
No data loaded
Upload a CSV or click Load demo data in the sidebar.
| Timestamp | Q_norm (%) | Rec (%) | θ (%) | y_H2 (%) | α | MB (%) | Status |
|---|---|---|---|---|---|---|---|
| No rows processed. | |||||||
Formulas
Normalized flow: Q_norm = (Q_H2_perm / Q_baseline) × 100 [%]
Recovery: Rec = (Q_H2_perm / Q_H2_feed) × 100 [%]
Stage cut: θ = (Qperm / Qfeed) × 100 [%]
Selectivity: α = (y_H2 / (100 - y_H2)) × (P_res / P_perm) [ideal]
Mass balance: gap = |Q_feed - (Q_perm + Q_res)| / Q_feed × 100 [%]
Alert Thresholds
Permeance drop: advisory at 5%, alarm at 10%. Perm H2 min 93 mol %. Recovery min 75%. Mass balance max 3% gap.
Scope
Reference-grade PoC. Single-stage hollow-fiber H2 separation. Real-time performance tracking, not design validation.
ΔP_LM via log-mean pressure difference. Material balances assume ideal gas behavior.